L26/P-784 “Automated assessment of follicle number per ovary for standardized detection of polycystic ovarian morphology”

Human Reproduction (2026)

Share this post

L26/P-784 “Automated assessment of follicle number per ovary for standardized detection of polycystic ovarian morphology”

P. Wygocki, A. Zapała, G. Dolanowski, M. Ulfig, M. Zieleń, M. Wrochna, K. Zieliński, N. Gajewska, D. Drzyzga, M. Brzozowski

An AI system (FOLLISCAN) counted follicles on 212 ovarian ultrasound cine-loops from 79 patients across five Polish clinics and was compared with routine clinical assessment for the ESHRE FNPO ≥20 PCOM criterion. Precision was similar (96% vs 93%), but AI sensitivity was far higher (79% vs 39%; McNemar p = 0.00097), with the biggest gains in borderline cases near the diagnostic cut-off.